Professional Fire Detection System
or Also called BOSCH fire detection & evacuation system
Choosing a fire alarm system isn’t just about adhering to legal requirements; it’s also about saving time, money and effort. The most common types of alarms that businesses use are conventional and addressable alarm systems. Both types of alarm link devices (such as call points and smoke detectors) to a main control panel. The main difference between the two is that with addressable fire alarm systems, you can pinpoint exactly which device has been activated.
Detection Reliability
Video-based Fire Detection
Intelligent detection. Superior protection
See it before it spreads
We believe in earliest and accurate fire detection as the crucial core of every fire detection system. We want to make sure that you can rely on our belief and therefore, we adopt the most elaborate technologies when developing our detectors.
Intelligent Signal Processing (ISP): algorithm for precise detection and differentiation of real fires and false alarms
Dual-Ray Technology: for even more precision
eSmog Feature: reliable detection and constant monitoring of electromagnetic pollution
Our AVIOTEC series represents a new generation in threat detection capabilities. Utilizing a unique, scientifically tested physical detection model, our technology spots fires and disturbances, predicts behavior to reduce false alarms and speeds reaction time – helping you stop threats before they spread. State-of-the-art fire detectors normally are installed at the ceiling. In case of a fire at floor level smoke has to reach the detector mounted at the ceiling. That’s why the detection time depends particularly on the height of the ceiling. The AVIOTEC series detects flames and smoke at the source and thus, provides reliable fire detection within seconds, especially in environments with high ceilings.

FIRE SAFETY & ALARM SYSTEM Need help deciding?

Need help deciding?
Call our product specialists at
(+88) 0170 4 170 255-57.
Addressable Detector
Conventional Detector

Every device connected to the addressable system has its own unique address. When a fire is detected, the device’s address shows up on the main control panel, telling you exactly which device has been activated. This will enable you to find the exact location of a fire and extinguish them quickly.

With a conventional system, there is no way of pinpointing the exact location of the fire. However, by wiring your building into different zones, you can get a general idea of where the fire is. For instance, if you have two floors, you could wire the first as ‘zone 1’ and the second as zone 2. So if a fire occurs in zone 1, you know that the fire is somewhere on the first floor.


Hydrants System


Every device connected to the addressable system has its own unique address. When a fire is detected, the device’s address shows up on the main control panel, telling you exactly which device has been activated. This will enable you to find the exact location of a fire and extinguish them quickly.There are two types of pressurized fire hydrants: wet-barrel and dry-barrel. In a wet-barrel design, the hydrant is connected directly to the pressurized water source.

Angle Hose Valve – UL Listed
Oblique Landing Valve – LPCB Approved
Single Jacket Lay-flat Fire Hose – UL Listed
Double Jacket Lay-flat Fire Hose – UL Listed
EMACO Angle Hose valve feature all brass construction with forged or cast bodies for rigidity and light weight. This Angle Hose Valve (90 degrees pattern) are for use in rack assemblies on standpipe having inlet and outlet opening of the same size or with the inlet larger than outlet or any other application which requires a listed fire hose valve.
EMACO Oblique Landing Valve is a type of globe pattern hydrant valve. These oblique type landing valves are available with flanged inlet or screwed inlet and are manufactured to comply to BS 5041 Part 1 standard with delivery hose connection and blank cap complying with BS 336:2010 standard. The landing valves are classified under low pressure and are suitable for use at nominal inlet pressure up to 15 bars. The internal casting finishes of every valve is of high quality ensuring a low flow restriction that meets the standard’s water flow test requirement.
EMACO single jacket lay-flat fire hose consists of plain-woven synthetic and TPU linings. Its warp is made by high strength polyester staple or filament. And weft from high strength polyester filament with low elongation (twill/plain weave).

There are special adhesive (solid or liquid) between the jacket and the hose, the hose is soft and highly polished, reduce the flow resistance. Thinner and more soft,lighter and more convenient to use High pressure resistance , low temperature resistance,anti-corrosion, aging resistance, wear-resisting.
Its Externally Elastometric Coated , All Synthetic, EPDM Rubber lined Fire Hose. Circularly woven jacket Coated with specially formulated Elastometric RED Coating for protection against abrasion, mild chemicals and heat. Its Inside Lining special grade synthetic, EPDM rubber used to form a high quality unified lining & covered resulting a compact unity by pillar adhesion to resist from deterioration and cracking.
Fire Hose Reel – LPCB Approved
Fog Nozzle- UL Listed
Spray Nozzle With Control Valve–Standard
Pillar Hydrant – Standard
EMACO Fire Hose Reels are designed and manufactured in manual versions with LPCB approved compliance of BS EN 671-1:2012 with semi-rigid hose complying with BS EN 694:2014 standards. EMACO fire hose reels provide a offhand fire fighting facility with a continuous supply of water available immediately.
EMACO industrial fog nozzles are manufactured to handle the rigors of industrial needs as the nozzles have adjustable annular orifice which enable the jet of water to be controlled from shut-off to a small jet through a large jet and then to a spray pattern by turning the rubber-tyred sleeve. These nozzles are made of cast bronze with adjustable fog, straight-stream & shut-off feature and are U.L. listed.
EMACO Lever Operated Jet-Spray Nozzle is a selectable gallonage branch pipe nozzle made from Aluminium Alloy and PVC which lightweight compact design makes it easier for firefighters to use and creates less torque from nozzle reaction increasing the overall control. Manufactured in reference to IS903, are supplied with a detachable 9mm nozzle which can be removed to reveal a 12mm nozzle.
EMACO two Way Fire (Pillar) Hydrants are Wet-barrel fre hydrants with two valve openings above the ground line. Made according to BS750 Standard for use in water-supply service outdoor areas where the climate is mild and freezing temperatures do not occur. Under normal operating conditions the entire interior of the hydrant is subjected to water pressure at all times.
Pin Hose Rack – Standard
Hose Rack Nipple – Standard
Hydrant Adapter – Standard
Class I, II, III Hydrant Box set – Standard
EMACO fre hose rack is a semi-automatic pin rack come pre-loaded with movable pins and an automatic release mechanism that keeps water out of the hose until the last fold is removed. This fire hose pin rack is built to ft around the brass adapter nipple, having pipe thread on one end, that thread in to the valve and hose thread on the other.
EMACO Rack Nipple is a cast brass hex nipple connector accessory, a fire hydrant adapter that has male NST threads on one side and male hose thread on the other used to connect fire hose to pipe threads in conjunction with the swinging hose rack.
EMACO Fire Hose Rack Adapter is a connector accessory, a ifre hydrant adapter that has female NST threads on one side and BS 336 female instantaneous on the other. This adapter is used to connect fire hose to pipe threads in conjunction with the swinging hose rack.
Class I Systems [2-1/2″ (64mm) hose connections are provided for use by fire departments and those trained in handling heavy water streams. Class II Systems [1-1/2″ (38mm) hose lines] are provided for use by trained building occupants until the fire department arrives. Class III Systems shall provide [1-1/2″ (38mm)] hose stations to supply water for use by trained building occupants.
Beaching Inlet – LPCB Approved
Breaching Inlets – Standard
Test and Drain Valve – UL Listed
Vortex Inhibitor
Breeching Inlets are installed outside the building or any easily accessible area in the building for firefighting purposes by fire brigade personnel to access the inlet. Breeching Inlets are fitted with inlet connection at fire brigade access level and outlet connection at specified points. It is normally dry but capable of being charged with water by pumping from fire service appliances.
EMACO Breeching Inlets give the fire department the capability of supplying the necessary water to the automatic sprinkler or standpipe system at a sufficient pressure without pressurizing the underground supply. Known as fire department connection (FDC), it is required by NFPA 13 & 14 as part of a water-based protection system as the auxiliary water supply, which serves as an alternative source of water.
The EMACO UL Listed Test & Drain Valve features single handle ball valve inspector’s test which eliminated the time and space consuming traditional loop assembly and provides both the test function and the express drain function for a wet fire sprinkler system. It also has large & integral sight glass allowing for maximum visibility when operated.
EMACO vortex inhibitor is a specialized pipe fitting used to prevent initiation of vortices within fire suction tank and air entrap into suction pipe. This vortex inhibitor is fitted with the port of suction pump pipe inlet to reduce vortices inside tank and ensure the suction pump working at its maximum efficiency, greatly minimizing the air entrainment to cause cavitation.


Pump & Water Works

NFPA20 Standard Fire Pump
WATER WORK BOOSTER PUMP SET
FIRE FIGHTING PUMP SET
Fire Fighting Pumps are specifically designed to meet the NFPA 20 and UL Listed. In addition, value added served by the certification which ensures the quality of system applied to each process of assembling, repair and other related services. EMACO on its commitment to be always at the service of his clients, offers a complete family of horizontal and vertical pumps for fire fighting packages complying with NFPA 20 and UL Listed.
EMACO has been providing large amount of fire fighting packages in recent decades driven by years of global experiences in producing quality pumps, valves, and related systems for energy, oil and gas, mining, water and sewage, as well as building services and industrial sectors. EMACO Fire Fighting Pumps are specifically designed to meet the NFPA 20 standard.
EMACO has been providing large amount of fire fighting packages in recent decades driven by years of global experiences in producing quality pumps, valves, and related systems for energy, oil and gas, mining, water and sewage, as well as building services and industrial sectors. EMACO Fire Fighting Pumps are specifically designed to meet the NFPA 20 standard.



Fire Extinguishers

Portable ABC Dry Powder– LPCB Approved
Portable CO2 – LPCB Approved
Portable AFFF Foam – LPCB Approved
Portable Water – LPCB Approved


Valve & Flow Control

Gate Valve – UL Listed
Butterfly Valve – UL
Check/Non-Return Valve – UL Listed
Y-Strainer – UL Listed